3000 Series Alarms Kongsberg 2000 series machines
Click on error code for possible cause.

3001 Wrong system tape loaded into control. internal
3003 Axis lag exceeds 16mm internal
3004 Hydraulic pump overloaded. Sheet 4 Plug 2 Pin-P
3006 Guard interlock. Sheet 5 Plug 3 Pin-b
3007 Loss of 24v supply in control. Fuse
3008 Tape reader misread sprocket hole. Tape fault
3009 High temperature in control cabinet. internal
3010 Dangerously high temperature in control cabinet. internal
3011 Axis drives disabled. Sheet 4 Plug 2 Pin-R
3012 Hydraulic filter blocked. Sheet 4 Plug 2 Pin-N
3013 Axis lubrication low or no air pressure. Sheet 4 Plug 2 Pin-M
3014 Hydraulic reservoir low. Sheet 4 Plug 2 Pin-L
3015 Very high current in axis drive. Sheet 4 Plug 2 Pin-B
3016 High temperature in spindle motor. internal
3017 Spindle motor drawing excess current for <5sec. Sheet 4 Plug 2 Pin-A
3018 Spindle motor overcurrent for >5sec. overload tripped. internal
3019 Spindle lubrication failure. Sheet 4 Plug 2 Pin-H
3020 X axis motor overtemperature. Sheet 4 plug 2 pin-F
3021 Y axis motor overtemperature. Sheet 4 plug 2 pin-E
3022 Z axis motor overtemperature. Sheet 4 plug 2 pin-D
3024 Loss of hydraulic pressure. Sheet 4 plug 2 pin-K
3025 Index table clutch slipped. Sheet 4 plug 2 pin-S
3110 Tap lubrication low. Sheet 5 Plug 3 Pin-S
3111 Coolant recirculation fault. Sheet 4 Plug 2 Pin-s
3181 X axis programmed into endstop. internal
3182 Y axis programmed into endstop. internal
3183 Z axis programmed into endstop. internal
3188 B axis programmed into endstop. internal
3301 X axis servo error. internal
3302 Y axis servo error. internal
3303 Z axis servo error. internal